Skip to content

Hydraulics & Circulation

15% of this exam

The most calculation-heavy domain on the trade exam. Three formulas — volume, turnover-to-flow, and filter area × rate — answer most of the math, and the concepts (TDH, friction loss, velocity limits, suction vs return) answer the rest. Practice the arithmetic until the only question is which formula applies.

What the exam asks

  • Pool volume in gallons for rectangular, circular and sloped-floor pools, using the right constant and the average depth.
  • Turnover math: flow from turnover time, turnover time from flow, and turnovers per day. Watch the divide-by-60.
  • Total dynamic head by adding the pieces or by reading the gauges, and what a loading filter does to flow.
  • Filter sizing in both directions: maximum flow from area, required area from flow.
  • Suction-side trouble, rough-in pressure testing and backwash: what each one looks like and what to do.

Part 1 of 5

Volume comes first

Every dosing and flow question starts from gallons. Get the shape, the depth and the constant right and the rest of the domain gets easier.

Volume math comes first

Rectangular: length × width × average depth × 7.5 gal/cu ft. Circular: 3.14 × radius² × average depth × 7.5 — square the radius, not the diameter; that's the classic trap. Every dosing and flow question starts from volume.

Work it: Rectangular pool volume

Gallons = Length × Width × Average depth × 7.5

ft
ft
ft

Cubic feet

60 ft × 30 ft × 5 ft equals 9,000 cu ft

Gallons

Cubic feet × 7.5 equals 67,500 gal

Work it: Circular pool volume

Gallons = 3.14 × Radius × Radius × Average depth × 7.5. Radius is half the diameter.

ft
ft

Surface area

3.14 × (20 ft ÷ 2) × (20 ft ÷ 2) equals 314 sq ft

Cubic feet

Surface area × 5 ft equals 1,570 cu ft

Gallons

Cubic feet × 7.5 equals 11,775 gal

Sloped floors use the average depth

For a floor that slopes at a constant grade, average the shallow and deep depths: (3 + 9) ÷ 2 = 6 ft. Then length × width × average depth gives cubic feet. Multiply by 7.5 for gallons, or by 7.48 when the problem gives the more exact constant. Using only the shallow or only the deep depth produces the planted wrong answers.

Work it: Volume with a sloped floor

Average depth = (Shallow + Deep) ÷ 2. Gallons = Length × Width × Average depth × 7.48.

ft
ft
ft
ft

Average depth

(3 ft + 9 ft) ÷ 2 equals 6 ft

Cubic feet

50 ft × 25 ft × average depth equals 7,500 cu ft

Gallons

Cubic feet × 7.48 equals 56,100 gal

In your books: Tab the handbook volume formula page and write the formula down before plugging numbers. The wrong answers are built from skipped steps.

Part 2 of 5

Turnover and flow rate

Turnover ties the pool's volume to the pump's flow. The same formula runs three ways, and the unit conversion is where most wrong answers come from.

Turnover converts to gpm in two steps

Volume ÷ turnover hours = gallons per hour, then ÷ 60 = gpm (36,000 gal ÷ 10 hr ÷ 60 = 60 gpm). Run it backward for turnover time: volume ÷ gpm = minutes. Forgetting the ÷ 60 is the built-in distractor.

Work it: Flow from turnover time

Flow in gpm = Volume ÷ Turnover hours ÷ 60

gal
hours

Gallons per hour

36,000 gal ÷ 10 hours equals 3,600 gph

Flow rate

Gallons per hour ÷ 60 equals 60 gpm

Turnover, three ways

Flow from turnover: volume ÷ hours ÷ 60. Turnover from flow: volume ÷ gpm ÷ 60 gives hours. Turnovers per day: gpm × 60 × 24 ÷ volume, so 120 gpm on a 43,200-gallon pool is 4 turnovers a day. Spas turn over in minutes, not hours: 800 gallons in 30 minutes is about 27 gpm.

Work it: Turnover time from flow

Turnover hours = Volume ÷ gpm ÷ 60

gal
gpm

Minutes per turnover

30,000 gal ÷ 100 gpm equals 300 min

Hours per turnover

Minutes ÷ 60 equals 5 hours

Work it: Turnovers per day

Turnovers per day = gpm × 60 × 24 ÷ Volume

gpm
gal

Gallons moved in a day

120 gpm × 60 × 24 equals 172,800 gal

Turnovers per day

Gallons moved ÷ 43,200 gal equals 4.0

Work it: Spa flow rate

Flow in gpm = Volume ÷ Turnover minutes

gal
min

Flow rate

800 gal ÷ 30 min equals 27 gpm

In your books: Tab the handbook turnover page. Watch units: turnover answers come out in minutes or hours, flow in gpm. Convert before picking a choice.

Part 3 of 5

Head, pump curves and what the pump does

A pump does not have one flow rating. What it delivers depends on how much resistance the system puts in front of it, so head is the idea that explains most pump questions.

The pump fights the whole system

Total dynamic head is every resistance the pump must overcome — pipe and fitting friction, equipment, elevation — and it sets where the pump lands on its curve. Friction loss rises roughly with the square of flow: double the flow, quadruple the loss. Slower is dramatically cheaper: pump power falls with the cube of speed, so half speed draws about one-eighth the power.

Work it: Friction and power when flow changes

Friction loss changes roughly with the square of the flow ratio. Pump power changes with about the cube of the speed ratio. Flow follows speed, so half speed is about half flow.

Speed ratio, and about the flow ratio

50 ÷ 100 equals 0.50

Friction loss as a multiple of the original (approximate)

Ratio × ratio equals 0.25×

Pump power as a multiple of the original (approximate)

Ratio × ratio × ratio equals 0.125×

TDH: add it up, or read it off the gauges

Total dynamic head is the static lift plus the friction on both sides of the pump: 5 + 10 + 25 = 40 ft. On a running system, add the discharge pressure to the suction vacuum, because one is above zero and one is below, and multiply by 2.31 to turn psi into feet of head. An 18 psi discharge and a 7 psi vacuum is 25 psi, about 58 ft.

Work it: TDH by addition

TDH = Static lift + Suction friction + Return friction

ft
ft
ft

Total dynamic head

5 ft + 10 ft + 25 ft equals 40 ft

Work it: TDH from the gauges

TDH = (Discharge psi + Suction vacuum in psi) × 2.31

psi
psi

Pressure rise across the pump

18 psi + 7 psi equals 25 psi

Total dynamic head

Pressure rise × 2.31 equals 58 ft

The pump runs where its curve meets the system

A centrifugal pump has no single flow rating. It has a curve of flow against head, and the piping has its own curve of resistance against flow. The pump operates where they cross. Longer runs, smaller pipe or a dirty filter add head, the operating point moves up the curve, and flow drops even though the motor speed has not changed.

In your books: Tab the handbook TDH page. Write the formula down before plugging numbers.

Part 4 of 5

Lines, filters and the surface

Each line has a job and a limit, the filter has to be sized to the flow, and most of the dirt is at the surface, so that is where the flow goes.

Each line has a job and a limit

Suction lines (skimmers, main drains → pump) are kept to about 6 ft/s; returns about 8 ft/s. The skimmer equalizer keeps the pump supplied with water if the level drops below the weir. Dual suction outlets are at least 3 feet apart or on different planes, so one bather can't block both.

Filter sizing works both directions

Maximum flow is filter area times the rated filtration rate; required area is design flow divided by the rate. High-rate sand runs around 15 gpm per square foot, DE only a few, and cartridge the slowest. A 3.14 sq ft sand filter handles 47 gpm; a 300 gpm pool needs 20 sq ft of sand. Filters piped in parallel split the flow, and one can be cleaned while the others run.

Work it: Maximum flow through a filter

Maximum flow = Filter area × Filtration rate

sq ft
gpm per sq ft

Maximum design flow

3.14 sq ft × 15 gpm per sq ft equals 47 gpm

Work it: Required filter area

Area = Design flow ÷ Filtration rate

gpm
gpm per sq ft

Filter area needed

300 gpm ÷ 15 gpm per sq ft equals 20 sq ft

The surface is where the dirt is

Most contamination floats, so the skimmers or gutter take most of the flow and the main drain takes a smaller share. The common convention is one skimmer for every 400 to 500 square feet of surface. The floating weir makes water spill in as a thin, fast sheet. A perimeter gutter needs surge capacity to absorb the water bathers displace.

Work it: Skimmer count

Skimmers = Surface area ÷ 400 to 500 sq ft per skimmer, rounded up

sq ft

At one per 500 sq ft, rounded up

2,000 sq ft ÷ 500 equals 4

At one per 400 sq ft, rounded up

2,000 sq ft ÷ 400 equals 5

Part 5 of 5

Trouble, testing and backwash

Suction-side problems look different from pressure-side ones. Buried piping has to be proven before it is covered, and backwash has its own end point and discharge rules.

Suction-side trouble looks different

The suction side runs below atmospheric pressure, so a leak there does not drip. It pulls in air: bubbles in the strainer pot, air at the returns, lost prime. Starve the suction and the pump cavitates, with a grinding noise and impeller damage. A pump set below water level has a flooded suction; one set above must be self-priming. Bleed trapped air at the filter's air relief after startup.

Test the pipe before it is buried

Once the shell is shot and the deck is poured, the piping is entombed. Cap every stub-out when rough-in is done, pressure test the lines, and keep them under pressure through the shell and deck phases so a gauge drop shows damage right away. For a finished pool losing water, the bucket test separates a leak from evaporation.

Backwash to the sight glass, and send it to waste

Backwash a sand filter until the sight glass runs clear, not for a fixed time. Backwash water goes to an approved waste point through an air gap, never back to the pool. A rate-of-flow indicator shows actual gpm so the operator can prove the pool is meeting its turnover. Before draining any pool, check the groundwater and open the hydrostatic relief so the shell does not float.

Know these cold

The short list to have in your head on exam day. Every line is also a card in your flashcards.

Gallons per cubic foot
7.5 — the constant in every volume problem
Flow from turnover
Volume ÷ hours ÷ 60 = gpm
Velocity limits (common practice)
~6 ft/s suction, ~8 ft/s return
Friction vs flow
Loss rises roughly with the square of flow rate
Pump affinity
Half speed ≈ half flow but only ~1/8 the power
Filter flow check
Design gpm ÷ filter area must not exceed the media's rated gpm/sq ft
Average depth, constant slope
(Shallow + deep) ÷ 2. A 3 ft to 9 ft floor averages 6 ft.
Exact gallons per cubic foot
7.48; 7.5 is the rounded working constant.
Turnovers per day
gpm × 60 × 24 ÷ volume (120 gpm, 43,200 gal = 4 per day).
Spa turnover
Figured in minutes: 800 gal ÷ 30 min ≈ 27 gpm.
TDH by addition
Static lift + suction friction + return friction (5 + 10 + 25 = 40 ft).
psi to feet of head
Multiply by 2.31 (20 psi = 46.2 ft).
TDH by gauges
(Discharge psi + suction vacuum in psi) × 2.31.
High-rate sand filter
About 15 gpm per sq ft. DE runs a few gpm per sq ft; cartridge is slowest.
Filter area
Design flow ÷ filtration rate (300 gpm ÷ 15 = 20 sq ft).
24-in. sand filter
About 3.14 sq ft of bed, good for about 47 gpm at 15 gpm per sq ft.
Skimmer count
About one per 400 to 500 sq ft of pool surface.
Operating point
Where the pump curve crosses the system curve. More head = less flow.
Suction-side leak
Draws air instead of dripping: bubbles in the strainer pot and at the returns.
Bucket test
A bucket on the step evaporates like the pool. If the pool drops more over about 24 hours, it is leaking.
Backwash end point
When the sight glass runs clear; discharge to waste through an air gap.

Where it lives in your books

The real exam is open book. Knowing which book and which tab answer this topic is worth as much as memorizing it.

Reading isn't learning. Retrieval is.

53 questions in this domain, each with an explanation and source.