Skip to content

Equipment & Electrical

15% of this exam

Pumps, filters, heaters, feeders and how they are installed and placed; NEC Article 680 — bonding, underwater lights, junction boxes, receptacles and the disconnect — which the exam tests as distances and wire sizes; and the construction equipment on a pool job (shotcrete rigs, concrete pumps, compressors, saws, cutting torches) with the OSHA rules that go with each.

What the exam asks

  • Filter types: who cleans how (backwash, precoat, remove and clean), fineness, and what a low or odd gauge reading means.
  • Heater questions: heat pump versus gas, what protects or kills an exchanger, BTU and COP math.
  • Pump, valve and feeder placement: flooded suction, check valves, and what goes last in line.
  • NEC Article 680 as distances and wire sizes: bonding, wet-niche lens depth, deck box, receptacle, disconnect.
  • OSHA rules for the tools on a pool job: torches, compressed air, concrete pumps, silica and shotcrete hoses.

Part 1 of 5

Filters and how to read them

Each filter type has its own cleaning ritual, and the gauge tells you when it is due. Exam questions usually hinge on one word: backwash, rinse, recirculate or precoat.

Know each filter's cleaning ritual

Sand: backwash, then rinse briefly to resettle the bed and flush dirty water to waste. DE: backwash, then recharge with fresh DE through the skimmer to precoat the grids — the powder is the actual filter medium. Cartridge: no backwash; remove and clean the element. Service trigger for all: pressure commonly 8–10 psi above the clean baseline.

The multiport valve is six answers waiting

Filter (normal), backwash (reverse flow to waste), rinse (resettle and flush after backwash), waste (bypass filter to drain — heavy vacuuming, lowering water), recirculate (circulate without filtering), closed (never run the pump on it).

Filter fineness and failure signs

DE traps the finest particles, down to a few microns; cartridge is in the middle and high-rate sand is the coarsest. Low gauge pressure with little dirt coming out on backwash means the sand bed has channeled. Sand at the return inlets means a cracked lateral or standpipe. Bumping a DE filter re-spreads the DE already on the elements and adds none. Clean a cartridge in order: rinse, degrease, then acid only if scale remains.

Worked example

Fig — Filter pressure service trigger
  1. Clean starting pressure12 psi

    Record it at startup — it's the baseline.

  2. Service trigger zone21 psi

    Backwash or clean at roughly 8–10 psi over the clean baseline.

In your books: Match the word in the question to the component's manual function before you read the choices.

Part 2 of 5

Pump, valves, feeders and placement

Where each piece sits on the equipment pad decides whether it works. The pump wants to sit close to the pool and low, and chemicals go in last.

Inside the pump

The strainer basket catches hair, lint and leaves before they reach the impeller; empty it as routine service. The mechanical seal keeps water from following the shaft into the motor, and its faces ride on a thin film of water. Run the pump dry and the seal overheats and fails. Every foot the pump sits above the water makes priming harder and cavitation more likely.

Valves and cleaners

A shared pool and spa system uses three-way diverter valves on the suction and the return, turned by actuators the controller commands. A suction-side cleaner runs on the pump's vacuum and sends debris to the strainer or filter. A pressure-side cleaner runs on return pressure, often with a booster pump, and carries its own bag. A robotic cleaner is self-contained and runs on low voltage.

Install equipment where it can work

Set the pump as close to the pool and as near to or below the water level as the site allows (flooded suction primes itself). Feeders go last in line after the heater with a check valve between them. Gas heaters need a noncombustible pad, clearances, combustion air and venting per the listing; heat pumps need open air on all sides so they do not recirculate their own cold discharge. Pressure-test lines with the trench open.

Feeders, probes and salt cells

Chemicals are injected last, after the filter and heater, with the chlorine and acid taps spaced apart. A peristaltic pump squeezes chemical through a tube with rollers, so the feed rate follows pump speed and the chemical never touches the mechanism. ORP is measured in millivolts and tracks oxidizing power; it is not a ppm reading. A salt cell reverses polarity on a timer to shed scale from its plates.

Part 3 of 5

Heating the water

Gas is fast, a heat pump is efficient, and solar borrows the sun. Know what each one needs to run, and what slowly destroys a heater.

Heaters: speed vs efficiency, and protect the exchanger

Gas heats fast regardless of air temperature; a heat pump moves heat from the air, delivering several units of heat per unit of electricity (COP > 1) but slowing as air cools. Pipe a bypass to keep exchanger flow in range, and put a check valve between the heater and a downstream tablet feeder so concentrated chlorine can't backflow and corrode it.

What kills a heater

A pressure or flow switch keeps the heater from firing unless enough water is moving through the exchanger; a variable-speed pump turned down too far will open it. Low pH from unbalanced trichlor eats the copper exchanger, and the copper shows up as blue-green stains at the returns. Gas heaters are installed to their listing and the fuel gas code: clearances, venting, combustion air and a gas line sized for the input.

Heat math: BTUs and COP

Heat needed = gallons × 8.34 × degrees of rise. Raising 20,000 gallons by 20°F takes 20,000 × 8.34 × 20 = 3,336,000 BTU. A heat pump's output is its electrical input times its COP: 6 kW at a COP of 5.0 delivers 30 kW of heat. It moves heat out of the air; it does not create it. Gas is the choice for heating a spa fast on a cold night.

Work it: BTUs to heat a pool

BTU = Gallons × 8.34 × Degrees of rise

gallons
°F

Pounds of water

20,000 gallons × 8.34 equals 166,800 lb

Heat needed

20,000 gallons × 8.34 × 20 °F equals 3,336,000 BTU

Work it: Heat pump output

Heat output = Electrical input × COP

kW

Heat delivered to the water

6 kW × 5 equals 30 kW

Solar heating is a bypass loop

A pool solar system sends the pool's own filtered water through the roof collectors and back. A controller compares a collector sensor with the water temperature and turns a motorized diverter valve only when the panels can add heat. A check valve stops short-circuiting and a vacuum breaker at the top lets the panels drain. Collector area runs roughly half to all of the pool's surface area.

Part 4 of 5

Electrical: Article 680

Article 680 reads as a list of distances and wire sizes. Bonding and GFCI answer different questions, so keep them apart.

Electrical and automation basics

Bonding ties metal parts to the same potential (shock-gradient protection); GFCI opens the circuit on small leakage currents (people protection) — they are different answers to different questions. Salt generators make chlorine from dissolved salt by electrolysis; freeze protection starts the pump near freezing because moving water resists freezing.

Article 680 is a list of distances

Bond the shell steel, perimeter surfaces within 3 ft, metal within 5 ft, light niches, equipment and the water itself with 8 AWG solid copper. Wet-niche lens at least 18 in. below the water (listed low-voltage: 4 in.). Deck junction box 4 in. above the deck, 8 in. above the water, 4 ft from the inside wall. Pump receptacle 6–10 ft from the water on GFCI; the maintenance disconnect within sight and at least 5 ft from the water.

More Article 680: disconnect, receptacles and low-voltage lights

The maintenance disconnect for the pump is within sight of the equipment, readily accessible, and at least 5 feet from the inside pool wall unless a permanent barrier separates it. General receptacles stay at least 6 feet from the pool, and a dwelling needs at least one between 6 and 20 feet. Low-voltage pool lights are fed only from a transformer listed for swimming pool use. Fiber optics carry light, not current.

Worked example

Fig — Article 680 distances from the inside pool wall
  1. Deck junction box, minimum4 ft
  2. Maintenance disconnect, minimum5 ft

    Also the zone where fixed metal must be bonded

  3. Nearest receptacle6 ft
  4. Farthest the required dwelling receptacle may be20 ft

In your books: Tab 680.21 through 680.26 and read the distance or wire size off the page rather than from memory. The wrong choices are the other numbers from the same article.

Part 5 of 5

Construction equipment and OSHA

A pool job brings torches, compressors, saws, concrete pumps and shotcrete rigs. Each one has its own OSHA rule.

Construction equipment has its own OSHA rules

Acetylene under 15 psig with flashback arrestors and a fire watch; compressed air for cleaning limited to 30 psi with chip guarding, whip checks on hose couplings; concrete pumps on outriggers with power-line clearance and the hose handled from the side; wet cutting or a vacuum shroud for silica; a shotcrete hose blockage cleared only with the air pressure relieved.

Know these cold

The short list to have in your head on exam day. Every line is also a card in your flashcards.

Dirty-filter signal
Gauge ~8–10 psi above clean starting pressure
DE after backwash
Must precoat grids with fresh DE via the skimmer
Cartridge filters
No backwash cycle — remove and clean the element
Heat pump COP
Moves heat from air; several units of heat per unit of electricity
Feeder check valve
Between heater and trichlor feeder to block corrosive backflow
Bonding vs GFCI
Bonding equalizes potential; GFCI trips on leakage current
NEC 680.26 bonding
8 AWG solid copper; deck within 3 ft, metal within 5 ft
NEC 680.23 wet-niche
Lens top ≥ 18 in. below water (listed low-voltage ≥ 4 in.)
NEC 680.24 deck box
≥ 4 in. above deck, ≥ 8 in. above water, ≥ 4 ft from the wall
NEC 680.22 pump receptacle
6–10 ft from the inside wall, GFCI protected
Filter fineness
DE finest (a few microns), then cartridge, then high-rate sand.
Channeled sand bed
Gauge stays low and backwash brings out little dirt, because water is passing through open channels.
Sand at the returns
A cracked lateral or standpipe inside the sand filter.
Bumping a DE filter
Shakes off the cake and redeposits the same DE. New DE goes in only after a backwash or teardown.
Cartridge cleaning order
Rinse, degrease, then acid only for remaining scale. Acid first sets the oils.
Heater flow switch
Pressure or flow switch stops the heater firing at low flow.
Blue-green stains at the returns
Copper from a heat exchanger attacked by low-pH water.
Heating BTUs
Gallons × 8.34 lb per gallon × °F rise.
Heat pump output
Electrical input × COP (6 kW × 5.0 = 30 kW).
Solar collector area
Roughly half to all of the pool's surface area.
ORP
Oxidation-reduction potential in millivolts: sanitizer activity, not ppm.
Peristaltic feed pump
Rollers squeeze a flexible tube; positive feed against line pressure.
Salt cell reverse polarity
Sheds calcium scale from the plates automatically.
Pump mechanical seal
Lubricated and cooled by a film of water. Never run the pump dry.
Maintenance disconnect
Within sight of the equipment, readily accessible, at least 5 ft from the inside pool wall.
Low-voltage pool lights
Fed from a transformer or power supply listed for swimming pool use (isolating type).
Perimeter bonding conductor
In the deck 18 to 24 in. from the water; the bonded perimeter extends 3 ft from the water's edge.
Dry DE powder
Contains silica. Handle gently, mix as a slurry, use respiratory protection.

Where it lives in your books

The real exam is open book. Knowing which book and which tab answer this topic is worth as much as memorizing it.

Reading isn't learning. Retrieval is.

63 questions in this domain, each with an explanation and source.