Skip to content
manual

Solar Thermal Manual — Solar Water and Pool Heating (FSEC)

The Florida Solar Energy Center's installer manual: collector types and orientation, direct and indirect system designs, freeze and scald protection, heat exchangers, controls, and pool heating. A free PDF — print and bind it. Solar is 5% of the plumbing trade exam.

15 questions in our bank cite this reference.

Short answer

Solar Thermal Manual: Solar Water & Pool Heating Manual is on the Florida Plumbing Trade Knowledge approved reference list in the 2006 edition. Our tab set marks 8 spots in book order, from Solar basics and collectors to Pool heating. 15 of our practice questions cite it.

On the state's approved list

The list entry this guide covers, in the printing the answer key follows. Check the cover before you tab.

  • Solar Thermal Manual: Solar Water & Pool Heating Manual2006 Free PDF · print & bind

    Florida Solar Energy Center (FSEC)

    Sold through Florida exam-book stores.

Editions match the DBPR reference lists (valid January 2026 – December 2026). Last checked September 25, 2026. Every question is reviewed by a Florida-licensed contractor who holds Certified Building and Class A HVAC licenses and has passed the state General Contractor exams.

The one thing to know

Solar questions are system-type questions. Decide whether the question describes a direct (open-loop), indirect (closed-loop glycol), drainback, or thermosiphon system first — the freeze-protection, heat-exchanger, and controller answers follow from the type.

Your tab set

Florida exams allow pre-tabbed, highlighted references. Place these tabs before exam day, in book order, and tick them off here.

Print tab labels

0 of 8 tabs placed

  1. 1
    Solar basics and collectors

    Insolation, flat-plate and evacuated-tube collectors, orientation toward true south, tilt roughly equal to latitude

  2. 2
    Direct (open-loop) systems

    Potable water through the collector; freeze protection by recirculation or drain-down; Florida's most common residential type

  3. 3
    Indirect (closed-loop) systems

    Propylene glycol loop, heat exchanger, expansion tank, charging and pressure; double-wall exchanger for toxic fluids

  4. 4
    Drainback systems

    Gravity drain to reservoir, continuous slope of exposed piping, pump sized for the lift

  5. 5
    Thermosiphon and ICS systems

    Tank above collector, no pump; integral collector storage

  6. 6
    Controls and pumps

    Differential temperature controller, sensor placement, pump selection

  7. 7
    Scald and overheat protection

    Tempering (anti-scald) valve on the solar tank outlet, pressure and temperature relief, stagnation

  8. 8
    Pool heating

    Unglazed collectors, flow rates, pool pump and bypass valve, controls

Highlight the question, underline the answer

Don't just tab your books — mark them as you practice. Every time a question sends you into a reference, leave a two-part mark behind: highlight the passage the question is about, and underline the exact words that answer it. Do this through your whole question bank and the book turns into a map of the tested material — so on exam day you recognize the spot, not just the section.

  1. 1

    Highlight what the question asks about

    When you look up a practice question, highlight the sentence or table the question turns on. That block is now a visual landmark you'll spot on a fast flip.

  2. 2

    Underline the exact answer

    Inside the highlight, underline the specific number, deadline, or phrase that is the answer — with a fine-tip pen. Highlight = the topic; underline = the fact.

  3. 3

    Color-code by what trips you up

    Use one highlighter color for deadlines and numbers, another for definitions, a third for the answers you got wrong twice. Your weak spots become the brightest marks in the book.

  4. 4

    Let your tabs and marks compound

    A tab gets you to the chapter; the highlight gets you to the paragraph; the underline gets you to the answer. Built up across a full question bank, that three-layer trail is the open-book skill the exam actually tests.

The reference lists allow underlining with pen or highlighter, bar handwritten and typewritten notes in the books, and bar making any marks during the exam — so every mark goes in before you walk in, and none of them can be written notes.

Navigating under time pressure

  • Collector orientation (true south, tilt near latitude), flat-plate vs evacuated-tube, and mounting are in the collector chapters near the front.
  • System types and their freeze protection (recirculation, drain-down, drainback, antifreeze) each have their own section — tab them side by side so you can compare.
  • Potable-water isolation (double-wall heat exchanger with toxic fluids), tempering valves, and relief valves are the code-overlap topics: the FBC-Plumbing water heater chapter says the same thing.
Exam domains this book answers

Frequently asked questions

Which edition of Solar Thermal Manual: Solar Water & Pool Heating Manual does the Florida exam use?

The 2006 edition, per the DBPR list for the Plumbing Trade Knowledge exam. The answer key follows that printing.

How should I tab FSEC Solar Thermal Manual for the exam?

Solar questions are system-type questions. Decide whether the question describes a direct (open-loop), indirect (closed-loop glycol), drainback, or thermosiphon system first — the freeze-protection, heat-exchanger, and controller answers follow from the type. Build the 8-tab set on this page before exam day, in book order, with permanent tabs that carry only the section heading; movable flags and written notes are not allowed in the exam room.

How do I find answers in FSEC Solar Thermal Manual quickly?

Collector orientation (true south, tilt near latitude), flat-plate vs evacuated-tube, and mounting are in the collector chapters near the front. System types and their freeze protection (recirculation, drain-down, drainback, antifreeze) each have their own section — tab them side by side so you can compare. Potable-water isolation (double-wall heat exchanger with toxic fluids), tempering valves, and relief valves are the code-overlap topics: the FBC-Plumbing water heater chapter says the same thing.

Sources

The official publications the editions and rules here trace to. The state's list controls when it differs from anything on this page.

Back to the full book list